Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
Talanta ; 217: 121028, 2020 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-32498897

RESUMO

Vitamin B12 is very important for human metabolism and its deficiency can cause anemia and the production of large red blood cells. An increased concentration of methylmalonic acid (MMA) is detected much before the transformation of blood cells, which thereby is an early indicator for mild or serious Vitamin B12 deficiency. A simple electrochemical sensor based on Palladium-Gold (PdAu) was developed by electrodeposition of PdAu nanoparticles on Polypyrrole (PPy) modified carbon fiber paper (CFP) electrode. The modified electrodes were characterized by High resolution transmission electron microscopy (HRTEM), Field emission scanning electron microscopy (FESEM) with energy-dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS) and electroanalytical techniques. Differential Pulse Voltammetric (DPV) studies have established that under optimum conditions, the developed sensor exhibits a broad linear dynamic range (4.01 pM - 52.5 nM) with a very low detection limit (1.32 pM). The proposed method was effectively applied in the non-enzymatic determination of MMA at an ultralow level in human blood serum and urine samples. The method displayed high selectivity toward MMA in the presence of other interfering substances.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Ácido Metilmalônico/análise , Papel , Deficiência de Vitamina B 12/diagnóstico , Biomarcadores/análise , Fibra de Carbono/química , Eletrodos , Ouro/química , Humanos , Estrutura Molecular , Paládio/química , Polímeros/química , Pirróis/química , Deficiência de Vitamina B 12/sangue , Deficiência de Vitamina B 12/urina
2.
Lakartidningen ; 1162019 Apr 02.
Artigo em Sueco | MEDLINE | ID: mdl-31192386

RESUMO

The aim of automated reflex testing is to achieve more rational and cost-effective use of laboratory investigations in clinical practice. In order to make use of this cost-effectiveness, the new tests should have a short implementation phase and clear objective goals. To accomplish an equal health care, the usage of new tests should have minimal variations between different primary health care units. We started a new model in Ostergotland County regarding clinical usage of new tests by active follow-up in two levels, both primary health care unit level and individual physician level, during the implementation phase. This study shows that active follow-up and feedback resulted in both shorter implementation phase and minimal variation between different primary health care units.


Assuntos
Técnicas de Laboratório Clínico/normas , Testes Diagnósticos de Rotina/normas , Ácido Metilmalônico/análise , Tireotropina/análise , Vitamina B 12/análise , Técnicas de Laboratório Clínico/métodos , Testes Diagnósticos de Rotina/métodos , Humanos , Modelos Teóricos , Atenção Primária à Saúde , Suécia
3.
Mol Imaging ; 16: 1536012116685941, 2017 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-28654376

RESUMO

PURPOSE: We investigated 2-(5-fluoro-pentyl)-2-methyl-malonic acid (18F-ML-10) positron emission tomography (PET) imaging of apoptosis posttherapy to determine optimal timing for predicting chemotherapy response in a mouse head/neck xenograft cancer model. PROCEDURES: BALB/c nude mice (4-8 weeks old) were implanted with UM-SCC-22B tumors. The treatment group received 2 doses of doxorubicin (10 mg/kg, days 0, 2). Small animal 18F-ML-10 PET/computed tomography was performed before and on days 1, 3, and 7 postchemotherapy. Using regions of interest around tumors, 18F-ML-10 uptake change was measured as %ID/g and uptake relative to liver. Terminal Uridine Nick-End Labeling (TUNEL) immunohistochemistry assay was performed using tumor samples of baseline and on days 1, 3, and 7 posttreatment. RESULTS: Treated mice demonstrated increased 18F-ML-10 uptake compared to baseline and controls, and 10 of 13 mice showed tumor volume decreases. All control mice showed tumor volume increases. Tumor-to-liver (T/L) ratios from the control group mice did not show significant change from baseline ( P > .05); however, T/L ratios of the treatment group showed significant 18F-ML-10 uptake differences from baseline compared to days 3 and 7 posttreatment ( P < .05), but no significant difference at 1 day posttreatment. CONCLUSION: 2-(5-Fluoro-pentyl)-2-methyl-malonic acid PET imaging has the potential for early assessment of treatment-induced apoptosis. Timing and image analysis strategies may require optimization, depending on the type of tumor and cancer treatment.


Assuntos
Apoptose/fisiologia , Fluordesoxiglucose F18/análise , Ácido Metilmalônico/análogos & derivados , Tomografia por Emissão de Pósitrons/métodos , Animais , Apoptose/efeitos dos fármacos , Linhagem Celular Tumoral , Doxorrubicina/farmacologia , Feminino , Humanos , Imuno-Histoquímica , Ácido Metilmalônico/análise , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Nus , Tomografia Computadorizada por Raios X , Ensaios Antitumorais Modelo de Xenoenxerto
4.
Rev. lab. clín ; 9(2): 40-47, abr.-jun. 2016. tab, graf
Artigo em Inglês | IBECS | ID: ibc-153437

RESUMO

Introduction. Homocysteine (Hcy) is a nonessential amino acid which links the methionine and the folate cycles. Hcy levels are increased in genetic disorders, such as classic homocystinuria and methylmalonic aciduria combined with homocystinuria. Other monogenic, multifactorial diseases and physiological conditions are also associated with high Hcy levels. The aim of this study is to validate a method to quantify Hcy in plasma. Material and methods. A method to quantify Hcy in plasma by HPLC was validated, by determining the following parameters: specificity, linearity, precision, accuracy, and detection and quantification limits according ICH and EMEA guidelines. Homocysteine was measured in 43 healthy individuals, 2 patients with high levels of methylmalonic acid, and a previously diagnosed patient with classic homocystinuria. Results. The method was able to identify and quantify Hcy without interferences. A linear behavior was observed in a range of 6-100 μM with r2 = 0.9967. The precision and accuracy studies showed variation coefficients under 6%. The limits of detection and quantification were 3.12 μM and 6.25 μM, respectively. The 43 healthy individuals studied had normal Hcy levels. The patient with elevated urinary methylmalonic acid levels and the homocystinuria patient showed high Hcy levels. Conclusion. The method is valid for the quantification of Hcy in plasma as it fulfills the requirements for validation of analytical methods. Its introduction into diagnostic and follow up algorithms is important in genetic diseases where this amino acid is increased (AU)


Introducción. La homocisteína (Hcy) es un aminoácido no esencial que enlaza el ciclo de la metionina con el ciclo del folato. Los niveles de Hcy se incrementan en trastornos genéticos como la homocistinuria clásica y la aciduria metilmalónica combinada con homocistinuria. Otras enfermedades monogénicas, multifactoriales y condiciones fisiológicas han sido asociadas con altos niveles de Hcy. El objetivo de este estudio es validar un método para la cuantificación de Hcy en plasma. Material y métodos. Se validó un método para la cuantificación de Hcy en plasma por HPLC. Se determinaron los parámetros de validación: especificidad, linealidad, precisión, exactitud, límite de detección y cuantificación según las guías ICH y EMEA. El método se aplicó en 43 individuos sanos, 2 con ácido metilmalónico elevado y uno con diagnóstico previo de homocistinuria clásica. Resultados. El método permitió la identificación y la cuantificación de la Hcy sin interferencias. Se observó un comportamiento lineal en un rango de 6-100 μM, con un r2 = 0,9967. En el estudio de precisión y exactitud se obtuvieron coeficientes de variación inferiores al 6%. Los límites de detección y cuantificación fueron de 3,12 y 6,25 μM, respectivamente. Los 43 individuos sanos mostraron niveles normales de Hcy. Uno de los pacientes con ácido metilmalónico elevado presentó niveles aumentados, igual que el paciente con homocistinuria. Conclusión. El método validado para la cuantificación de Hcy en plasma cumple con los criterios para la validación de métodos analíticos. Su introducción en los algoritmos de diagnóstico y seguimiento es importante en las enfermedades genéticas que cursan con incremento de este aminoácido (AU)


Assuntos
Humanos , Masculino , Recém-Nascido , Lactente , Pré-Escolar , Criança , Adulto , Cromatografia Líquida de Alta Pressão/instrumentação , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida de Alta Pressão , Homocisteína/análise , Homocisteína/sangue , Plasma/metabolismo , Ácido Metilmalônico/análise , Homocistinúria/sangue , Homocistinúria/diagnóstico , Homocistinúria/patologia , Cromatografia/métodos , Cromatografia
5.
Clin Biochem ; 47(1-2): 82-6, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23965230

RESUMO

BACKGROUND: Vitamin B12 insufficiency/deficiency is common in mixed patient populations. However there is no single marker which can reliably diagnose B12 insufficiency/deficiency. Elevated concentrations of methylmalonic acid (MMA) are considered the most representative marker of metabolic vitamin B12 insufficiency, but poor assay availability limits clinical utility. Low concentrations of serum vitamin B12 are often used to assess vitamin B12 status but this approach generates a high rate of false negative results. Emerging evidence indicates that holotranscobalamin (holoTC) may be a more reliable indicator of vitamin B12 status. AIMS AND METHODS: We substituted serum vitamin B12 measurement with holoTC, supported by MMA in patients referred for assessment of vitamin B12 status. A service evaluation was undertaken of the pattern of MMA values obtained for patients with holoTC 25-50 pmol/L (an indeterminate result). MMA cut-offs of 280 and 360 nmol/L were applied for patients ≤ 65 or >65 years respectively. RESULTS: A total of 4,175 consecutive patients were investigated and MMA was analysed for 19% of patients. The incidence of elevated MMA was 41% (holoTC, 25-29 pmol/L), 32% (30-34 pmol/L), 33% (35-39 pmol/L), 30% (40-44 pmol/L), and 26% (45-50 pmol/L). CONCLUSIONS: Our results indicate that in the clinical setting a holoTC between 25 and 50 pmol/L is a poor predictor for the concentration of MMA provided the goal is to identify patients with MMA values above the limits used in the present study. Further studies are needed to evaluate to what extent holoTC <25 and >50 pmol/L reflect circulatory MMA concentrations.


Assuntos
Ácido Metilmalônico/análise , Transcobalaminas/análise , Vitamina B 12/sangue , Biomarcadores/sangue , Humanos
6.
Nutr. hosp ; 28(5): 1447-1452, sept.-oct. 2013. ilus, tab
Artigo em Inglês | IBECS | ID: ibc-120352

RESUMO

BACKGROUND: The elderly population is particularly at risk for developing vitamin B12-deficiency. Serum cobalamin does not necessarily reflect a normal B12 status. The determination of methylmalonic acid is not available in all laboratories. Issues of sensitivity for holotranscobalamin and the low specificity of total homocysteine limit their utility. The aim of the present study is to establish a diagnostic algorithm by using a combination of these markers in place of a single measurement.METHODS: We compared the diagnostic efficiency of these markers for detection of vitamin B12 deficiency in a population (n = 218) of institutionalized elderly (median age 80 years). Biochemical, haematological and morphological data were used to categorize people with or without vitamin B12 deficiency.RESULTS: In receiver operating curves characteristics for detection on vitamin B12 deficiency using single measurements, serum folate has the greatest area under the curve (0.87) and homocysteine the lowest (0.67). The best specificity was observed for erythrocyte folate and methylmalonic acid (100% for both) but their sensitivity was very low (17% and 53%, respectively). The highest sensitivity was observed for homocysteine (81%) and serum folate (74%). When we combined these markers, starting with serum and erythrocyte folate, followed by holotranscobalamin and ending by methylmalonic acid measurements, the overall sensitivity and specificity of the algorithm were 100% and 90%, respectively.CONCLUSION: The proposed algorithm, which combines erythrocyte folate, serum folate, holotranscobalamin and methylmalonic acid, but eliminate B12 and tHcy measurements, is a useful alternative for vitamin B12 deficiency screening in an elderly institutionalized cohort (AU)


Introducción: Los mayores son una población que presenta un riesgo importante de desarrollar una deficiencia de vitamina B12, pero las concentraciones de cobalamina en suero no reflejan necesariamente un estado abnormal en el estado de B12. Existen biomarcadores asociados a la vitamina B12: el ácido metilmalónico no está disponible en todos los laboratorios, la holotranscobalamina es poco sensible y la homocisteína presenta una baja especificidad. El objetivo del presente estudio es establecer un algoritmo de diagnóstico mediante el uso de una combinación de estos biomarcadores en lugar de la medición de uno sólo de ellos. Métodos: Se comparó la eficacia diagnóstica de estos marcadores para la detección de deficiencia de vitamina B12 en una población (n = 218) de ancianos institucionalizados (edad media 80 años). Los parámetros bioquímicos, hematológicos y morfológicos fueron utilizados para clasificar a los sujetos con o sin deficiencia de vitamina B12. Resultados: Se establecieron las curvas ROC (Receiver Operating Curves) para determinar la eficacia diagnóstica de cada parámetro, tomado individualmente. El folato sérico tenía la mayor área bajo la curva (0,87) y la homocisteína la más baja (0,67). Se observó que la mejor especificidad la presentaba el folato eritrocitario y el ácido metilmalónico (100% para ambos), pero sus sensibilidades eran muy bajas (17% y 53%, respectivamente). Y se observó que la sensibilidad más alta la presentaba la homocisteína (81%) y el folato sérico (74%), pero en contrapartida una especificidad baja. Cuando se combinaron estos marcadores, iniciando las determinaciones con el folato sérco y eritrocitario, seguido por holotranscobalamina y terminando por las mediciones de ácido metilmalónico, la sensibilidad y especificidad global del algoritmo fueron 100% y 90%, respectivamente. Conclusión: El algoritmo propuesto, que combina la determinación de folato sérico y eritrocitario, holotranscobalamina y ácido metilmalónico, sin necesidad de evaluar la vitamina B12 y la homocisteína, es una alternativa útil para la detección de un estado abnormal del estado de vitamina B12 en una población de ancianos institucionalizados (AU)


Assuntos
Humanos , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Deficiência de Vitamina B 12/diagnóstico , Ácido Fólico/sangue , Transcobalaminas/análise , Ácido Metilmalônico/análise , Homocisteína/análise , Envelhecimento/fisiologia , Risco Ajustado/métodos , População Institucionalizada , Reprodutibilidade dos Testes , Biomarcadores/análise
7.
PLoS One ; 8(9): e75312, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24073261

RESUMO

Coß-4-ethylphenyl-cob(III) alamin (EtPhCbl) is an organometallic analogue of vitamin B12 (CNCbl) which binds to transcobalamin (TC), a plasma protein that facilitates the cellular uptake of cobalamin (Cbl). In vitro assays with key enzymes do not convert EtPhCbl to the active coenzyme forms of Cbl suggesting that administration of EtPhCbl may cause cellular Cbl deficiency. Here, we investigate the in vivo effect of EtPhCbl in mice and its ability, if any, to induce Cbl deficiency. We show that EtPhCbl binds to mouse TC and we examined mice that received 3.5 nmol/24h EtPhCbl (n=6), 3.5 nmol/24h CNCbl (n=7) or NaCl (control group) (n=5) through osmotic mini-pumps for four weeks. We analyzed plasma, urine, liver, spleen, submaxillary glands and spinal cord for Cbl and markers of Cbl deficiency including methylmalonic acid (MMA) and homocysteine (tHcy). Plasma MMA (mean±SEM) was elevated in animals treated with EtPhCbl (1.01±0.12 µmol/L) compared to controls (0.30±0.02 µmol/L) and CNCbl (0.29±0.01 µmol/L) treated animals. The same pattern was observed for tHcy. Plasma total Cbl concentration was higher in animals treated with EtPhCbl (128.82±1.87 nmol/L) than in CNCbl treated animals (87.64±0.93 nmol/L). However, the organ levels of total Cbl were significantly lower in animals treated with EtPhCbl compared to CNCbl treated animals or controls, notably in the liver (157.07±8.56 pmol/g vs. 603.85±20.02 pmol/g, and 443.09±12.32 pmol/g, respectively). Differences between the three groups was analysed using one-way ANOVA and, Bonferroni post-hoc test. EtPhCbl was present in all tissues, except the spinal cord, accounting for 35-90% of total Cbl. In conclusion, treatment with EtPhCbl induces biochemical evidence of Cbl deficiency. This may in part be caused by a compromised tissue accumulation of Cbl.


Assuntos
Biomarcadores/análise , Transcobalaminas/metabolismo , Deficiência de Vitamina B 12/induzido quimicamente , Vitamina B 12/análogos & derivados , Vitamina B 12/farmacocinética , Animais , Feminino , Ácido Metilmalônico/análise , Camundongos , Estrutura Molecular , Distribuição Tecidual , Vitamina B 12/toxicidade , Deficiência de Vitamina B 12/metabolismo
8.
Anal Bioanal Chem ; 400(7): 1953-8, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21360031

RESUMO

Methylmalonic aciduria is a common inherited metabolic disorder. Methylmalonic acid (MMA), a key indicator of methylmalonic aciduria, increases in the amniotic fluid of affected fetuses. For prenatal diagnosis, the MMA in amniotic fluid can be measured by stable-isotope dilution gas chromatography-mass spectrometry. Here, we quantified the MMA in cell-free amniotic fluid samples that had been dried on filter paper and transported at ambient temperatures, and compared the results with data obtained from the original amniotic fluid. Our results indicated that the filter paper method was reproducible and accurate enough to be applied to clinical analysis. We also used the filter paper method to screen at-risk fetuses and obtained a clear diagnosis in each case. We conclude that our method enables the prenatal diagnosis of methylmalonic aciduria using practical procedures and a simplified method for transporting the samples.


Assuntos
Erros Inatos do Metabolismo dos Aminoácidos/diagnóstico , Líquido Amniótico/química , Ácido Metilmalônico/análise , Diagnóstico Pré-Natal , Erros Inatos do Metabolismo dos Aminoácidos/urina , Feminino , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Ácido Metilmalônico/urina , Gravidez , Reprodutibilidade dos Testes
9.
Cell Res ; 19(5): 625-37, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19223854

RESUMO

Apoptosis plays a pivotal role in the etiology or pathogenesis of numerous medical disorders, and thus, targeting of apoptotic cells may substantially advance patient care. In our quest for novel low-molecular-weight probes for apoptosis, we focused on the uncommon amino acid gamma-carboxyglutamic acid (Gla), which plays a vital role in the binding of clotting factors to negatively charged phospholipid surfaces. Based on the alkyl-malonic acid motif of Gla, we have developed and now present ML-10 (2-(5-fluoro-pentyl)-2-methyl-malonic acid, MW=206 Da), the prototypical member of a novel family of small-molecule detectors of apoptosis. ML-10 was found to perform selective uptake and accumulation in apoptotic cells, while being excluded from either viable or necrotic cells. ML-10 uptake correlates with the apoptotic hallmarks of caspase activation, Annexin-V binding and disruption of mitochondrial membrane potential. The malonate moiety was found to be crucial for ML-10 function in apoptosis detection. ML-10 responds to a unique complex of features of the cell in early apoptosis, comprising irreversible loss of membrane potential, permanent acidification of cell membrane and cytoplasm, and preservation of membrane integrity. ML-10 is therefore the most compact apoptosis probe known to date. Due to its fluorine atom, ML-10 is amenable to radio-labeling with the (18)F isotope, towards its potential future use for clinical positron emission tomography imaging of apoptosis.


Assuntos
Ácido 1-Carboxiglutâmico/química , Apoptose , Corantes Fluorescentes/química , Ácido Metilmalônico/análogos & derivados , Anexina A5/metabolismo , Linhagem Celular , Desenho de Fármacos , Corantes Fluorescentes/análise , Células HeLa , Humanos , Concentração de Íons de Hidrogênio , Células Jurkat , Potenciais da Membrana , Ácido Metilmalônico/análise , Ácido Metilmalônico/química , Tomografia por Emissão de Pósitrons , Fatores de Tempo
10.
J Bacteriol ; 191(8): 2899-901, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19233926

RESUMO

Genome sequence information suggests that B(12)-dependent mutases are present in a number of bacteria, including members of the suborder Corynebacterineae like Mycobacterium tuberculosis and Corynebacterium glutamicum. We here functionally identify a methylmalonyl coenzyme A (CoA) mutase in C. glutamicum that is retained in all of the members of the suborder Corynebacterineae and is encoded by NCgl1471, NCgl1472, and NCgl1470. In addition, we observe the presence of methylmalonate in C. glutamicum, reaching concentrations of up to 757 nmol g (dry weight)(-1) in propionate-grown cells, whereas in Escherichia coli no methylmalonate was detectable. As demonstrated with a mutase deletion mutant, the presence of methylmalonate in C. glutamicum is independent of mutase activity but possibly due to propionyl-CoA carboxylase activity. During growth on propionate, increased mutase activity has severe cellular consequences, resulting in growth arrest and excretion of succinate. The physiological context of the mutase present in members of the suborder Corynebacterineae is discussed.


Assuntos
Acil Coenzima A/metabolismo , Corynebacterium glutamicum/enzimologia , Metilmalonil-CoA Mutase/genética , Metilmalonil-CoA Mutase/metabolismo , Proteínas de Bactérias/genética , Proteínas de Bactérias/metabolismo , Corynebacterium glutamicum/química , Corynebacterium glutamicum/genética , Corynebacterium glutamicum/crescimento & desenvolvimento , Escherichia coli/química , Deleção de Genes , Ácido Metilmalônico/análise , Metilmalonil-CoA Descarboxilase/metabolismo , Propionatos/metabolismo , Ácido Succínico/metabolismo
11.
Apoptosis ; 14(3): 257-67, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19172398

RESUMO

Utilization of molecular imaging of apoptosis for clinical monitoring of tumor response to anti-cancer treatments in vivo is highly desirable. To address this need, we now present ML-9 (butyl-2-methyl-malonic acid; MW = 173), a rationally designed small-molecule detector of apoptosis, based on a novel alkyl-malonate motif. In proof-of-concept studies, induction of apoptosis in tumor cells by various triggers both in vitro and in vivo was associated with marked uptake of (3)H-ML-9 administered in vivo, in correlation with the apoptotic hallmarks of DNA fragmentation, caspase-3 activation and membrane phospholipid scrambling, and with correlative tumor regression. ML-9 uptake following chemotherapy was tumor-specific, with rapid clearance of the tracer from the blood and other non-target organs. Excess of non-labeled "cold" compound competitively blocked ML-9 tumor uptake, thus demonstrating the specificity of ML-9 binding. ML-9 may therefore serve as a platform for a novel class of small-molecule imaging agents for apoptosis, useful for assessment of tumor responsiveness to treatment.


Assuntos
Apoptose , Monitoramento de Medicamentos , Ácido Metilmalônico/análogos & derivados , Neoplasias/tratamento farmacológico , Animais , Antibióticos Antineoplásicos/uso terapêutico , Antimetabólitos Antineoplásicos/uso terapêutico , Antineoplásicos Alquilantes/uso terapêutico , Biomarcadores/análise , Biomarcadores/metabolismo , Carmustina/uso terapêutico , Linhagem Celular Tumoral , Doxorrubicina/uso terapêutico , Fluoruracila/uso terapêutico , Humanos , Células Jurkat , Malonatos/química , Ácido Metilmalônico/análise , Ácido Metilmalônico/metabolismo , Camundongos , Camundongos Endogâmicos BALB C , Neoplasias/química , Neoplasias/patologia
12.
Anal Chem ; 80(15): 5776-82, 2008 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-18572955

RESUMO

Methylmalonic acid and total homocysteine belong to useful clinical indicators of cobalamin and folate status and are commonly measured separately. A sensitive and rapid method has been developed for simultaneous determination of both biomarkers and related metabolites in serum or plasma by isotope dilution gas chromatography-mass spectrometry (GC/MS). Thiols bound in disulfide bonds were released with 2,3-dimercapto-1-propanesulfonic acid (DMPS), and after deproteinization, they were phase-transfer derivatized with heptafluorobutyl chloroformate (HFBCF) in a single step. The reducing capability of the DMPS agent was comparable to that of the dithiothreitol, but exceeded the latter in much cleaner extracts obtained. The new method enabled GC/MS screening of amino acidic metabolites, including cystathionine and thiol-containing dipeptides, as their N(S,O)-heptafluorobutoxycarbonyl heptafluorobutyl ester derivatives in serum or plasma. Accurate quantitation of seven biomarkers was accomplished by using deuterated internal standards; the detection limits ranged from 7 to 20 nmol/L, the between-day precision from 1.5 to 8.8%, and the recoveries were between 83 and 103%. The results suggest that the new combined procedure of DMPS reduction and HFBCF derivatization make the method efficient for diagnostics of folate and cobalamin status as well as for screening of amino acidic metabolites in body fluids.


Assuntos
Fluorocarbonos/química , Ácido Fólico/sangue , Formiatos/química , Cromatografia Gasosa-Espectrometria de Massas/métodos , Homocisteína/análise , Ácido Metilmalônico/análise , Vitamina B 12/sangue , Ácidos Alcanossulfônicos , Biomarcadores , Cromatografia Gasosa-Espectrometria de Massas/normas , Humanos , Oxirredução , Compostos de Sulfidrila/química
14.
Brain ; 130(Pt 3): 853-61, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17287286

RESUMO

We have identified 12 patients with autosomal recessive mitochondrial encephalomyopathy with elevated methylmalonic acid. The disorder has a high incidence of 1 in 1700 in the Faroe Islands due to a founder effect, and a carrier frequency of 1 in 33. The symptoms comprise hypotonia, muscle atrophy, hyperkinesia, severe hearing impairment and postnatal growth retardation. Neuroimaging showed demyelination and central and cortical atrophy, including atrophy of the basal ganglia, and some of the patients fulfilled the criteria for Leigh syndrome. Urine and plasma methylmalonic acid were elevated. Homozygosity mapping with the Affymetrix 10 K array revealed a homozygous region on chromosome 13q14 harbouring the SUCLA2 gene. Mutations in SUCLA2 were recently shown to cause a similar disorder in a small Israeli family. Mutation analysis identified a novel splice site mutation in SUCLA2, IVS4 + 1G --> A, leading to skipping of exon 4. The SUCLA2 gene encodes the ATP-forming beta subunit of the Krebs cycle enzyme succinyl-CoA ligase. The hallmark of the condition, elevated methylmalonic acid, can be explained by an accumulation of the substrate of the enzyme, succinyl-CoA, which in turn leads to elevated methylmalonic acid, because the conversion of methylmalonyl-CoA to succinyl-CoA is inhibited.


Assuntos
Ácido Metilmalônico/análise , Encefalomiopatias Mitocondriais/genética , Succinato-CoA Ligases/genética , Adolescente , Adulto , Ilhas Atlânticas/epidemiologia , Criança , Pré-Escolar , Análise Mutacional de DNA/métodos , DNA Mitocondrial/genética , Saúde da Família , Feminino , Genes Recessivos/genética , Haplótipos , Humanos , Incidência , Masculino , Repetições de Microssatélites/genética , Encefalomiopatias Mitocondriais/complicações , Encefalomiopatias Mitocondriais/epidemiologia , Músculo Esquelético/enzimologia , Músculo Esquelético/patologia , Mutação/genética , Linhagem , Polimorfismo de Nucleotídeo Único/genética
16.
Artigo em Inglês | MEDLINE | ID: mdl-15908288

RESUMO

We performed prenatal diagnosis of organic acid disorders using two mass spectrometric methods; gas chromatography mass spectrometry (GC/MS) and tandem mass spectrometry (ESI/MS/MS). Of 28 cases whose amniotic fluid was tested, 11 cases were diagnosed as "affected". All cases whose samples were diagnosed as "unaffected" were confirmed to have no symptoms or abnormalities in urinary organic acid analysis after birth. Of the 11 "affected" cases, two cases were missed by ESI/MS/MS but not by GC/MS. When the stability of metabolites in amniotic fluid was checked, it was found that acylcarnitines degraded in one week at room temperature, whereas organic acids such as methylmalonate or methylcitrate were stable for at least 14 days. Prenatal diagnosis by analysis using simultaneous two or more methods may be more reliable, though attention should be paid to sample transportation conditions.


Assuntos
Líquido Amniótico/química , Doenças Fetais/diagnóstico , Espectrometria de Massas/métodos , Erros Inatos do Metabolismo/diagnóstico , Diagnóstico Pré-Natal/métodos , Ácidos Carboxílicos/metabolismo , Carnitina/análogos & derivados , Carnitina/análise , Feminino , Cromatografia Gasosa-Espectrometria de Massas/métodos , Glutaratos/análise , Humanos , Erros Inatos do Metabolismo/metabolismo , Ácido Metilmalônico/análise , Gravidez , Propionatos/análise , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização por Electrospray/métodos , Temperatura
17.
Clin Biochem ; 38(4): 319-27, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15766733

RESUMO

OBJECTIVES: The necessity of confirmation of compound identity in quantitative analysis is well recognized for methods utilizing single mass spectrometry detection but is not commonly addressed for applications utilizing multiple-stage mass spectrometry (MSn). For MSn detection, no commonly accepted rules for assessment of analytical specificity in quantitative analyses have been established to date. METHODS: To assure compound identity, we evaluated approaches based on monitoring multiple mass transitions of a target compound followed by comparison of the branching ratios of the mass transitions. RESULTS: Monitoring multiple mass transitions along with evaluation of the ratio of their relative intensities allows the analyst to distinguish the target analyte from interferences in quantitative analysis. The strategy and the acceptance criteria are compound and method specific and should be established during the method development and validation. CONCLUSIONS: The certainty of analyte identity is very important in quantitative analysis using MSn detection; methods to verify analyte identity should be used in all critical applications.


Assuntos
Espectrometria de Massas/métodos , Espectrometria de Massas/normas , Cortisona/análise , Humanos , Imunossupressores/análise , Isótopos , Ácido Metilmalônico/análise , Valores de Referência , Sensibilidade e Especificidade , Sirolimo/análise , Testosterona/análise
18.
Artigo em Inglês | MEDLINE | ID: mdl-15315171

RESUMO

To evaluate the implication of methymalonic acid (MMA) in the early diagnosis of neural tube defects (NTD), a quantitative assay for MMA was established by using gas chromatography-mass spectrometry with stable isotope of MMA as an internal standard. Amniotic fluid and maternal urine MMA concentration, maternal serum folate, red blood cell folate and vitamin B12 levels were measured in the middle term of NTD-affected and normal pregnancies. Amniotic fluid and maternal urine MMA concentrations in the middle term of NTD affected pregnancies (1.4 +/- 0.9 micromol/L, and 22.1 +/- 12.6 nmol/micromol creatinine) were significantly higher than that of normal pregnancies (1.0 +/- 0. 4 micromol/L, and 2.5 +/- 1.1 nmol/micromol creatinine). There was no significant difference between normal and NTD pregnancies for serum folate, red blood cell folate and vitamin B12 levels. The results suggested that MMAs in amniotic fluid and maternal urine are sensitive markers for early diagnosis of NTD. Vitamin B12 is an active cofactor involved in the remethylation of homocycteine and its deficiency is an independent risk factor for NTD. MMA is a specific and sensitive marker for intracellular vitamin B12 deficiency. This study suggests that it is necessary to monitor the vitamin B12 deficiency and advocates vitamin B12 supplementation with folate prevention program.


Assuntos
Líquido Amniótico/química , Ácido Metilmalônico/urina , Defeitos do Tubo Neural/diagnóstico , Diagnóstico Pré-Natal , Adulto , Biomarcadores/análise , Biomarcadores/urina , Feminino , Ácido Fólico/sangue , Humanos , Ácido Metilmalônico/análise , Defeitos do Tubo Neural/metabolismo , Gravidez , Segundo Trimestre da Gravidez , Vitamina B 12/sangue
19.
Pediatr Radiol ; 34(7): 580-2, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15205843

RESUMO

Methylmalonic acidemia (MMA) is a multifactorial autosomal recessive inborn error of organic acid metabolism, often presenting with neurologic findings. We report the imaging findings in a case of a child with classic neurological and laboratory findings for MMA. Imaging studies demonstrated abnormalities within the basal ganglia, particularly the globi pallidi (GP). Diffusion-weighted abnormalities seen in patients with MMA during an acute episode of metabolic acidosis and at follow-up are discussed. The authors are aware of only one prior report of serial examinations demonstrating resolution of restricted diffusion in the GP. The biochemical and pathophysiologic basis of the imaging findings of MMA are explained.


Assuntos
Encefalopatias Metabólicas Congênitas/patologia , Imagem de Difusão por Ressonância Magnética , Ácido Metilmalônico/análise , Encefalopatias Metabólicas Congênitas/tratamento farmacológico , Pré-Escolar , Globo Pálido/patologia , Humanos
20.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-634128

RESUMO

To evaluate the implication of methymalonic acid (MMA) in the early diagnosis of neural tube defects (NTD), a quantitative assay for MMA was established by using gas chromatography-mass spectrometry with stable isotope of MMA as an internal standard. Amniotic fluid and maternal urine MMA concentration, maternal serum folate, red blood cell folate and vitamin B12 levels were measured in the middle term of NTD-affected and normal pregnancies. Amniotic fluid and maternal urine MMA concentrations in the middle term of NTD affected pregnancies (1.4 +/- 0.9 micromol/L, and 22.1 +/- 12.6 nmol/micromol creatinine) were significantly higher than that of normal pregnancies (1.0 +/- 0. 4 micromol/L, and 2.5 +/- 1.1 nmol/micromol creatinine). There was no significant difference between normal and NTD pregnancies for serum folate, red blood cell folate and vitamin B12 levels. The results suggested that MMAs in amniotic fluid and maternal urine are sensitive markers for early diagnosis of NTD. Vitamin B12 is an active cofactor involved in the remethylation of homocycteine and its deficiency is an independent risk factor for NTD. MMA is a specific and sensitive marker for intracellular vitamin B12 deficiency. This study suggests that it is necessary to monitor the vitamin B12 deficiency and advocates vitamin B12 supplementation with folate prevention program.


Assuntos
Líquido Amniótico/química , Biomarcadores/análise , Biomarcadores/urina , Ácido Fólico/sangue , Ácido Metilmalônico/análise , Ácido Metilmalônico/urina , Defeitos do Tubo Neural/diagnóstico , Defeitos do Tubo Neural/metabolismo , Segundo Trimestre da Gravidez , Diagnóstico Pré-Natal , Vitamina B 12/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...